Criterion: Industrial Hygiene

Version 5.0.0 | Status: Active
Supersedes: 4.0.0
UN conformity topic code:

Requirements for controlling worker exposure to chemical, biological, and physical hazards

Full Description

B4. Industrial Hygiene

Code 8.0

Worker exposure to chemical, biological, and physical agents shall be identified, evaluated, and controlled according to the Hierarchy of Controls. When hazards cannot be adequately controlled, workers shall be provided with and use appropriate, well-maintained, personal protective equipment free of charge. Participants shall provide workers with safe and healthy working environments, which shall be maintained through ongoing, systematic monitoring of workers' health and working environments. Participants shall provide occupational health monitoring to routinely evaluate if workers' health is being harmed from occupational exposures. Protective occupational health programs shall be ongoing and include educational materials about the risks associated with exposure to workplace hazards.

Minimum Conformance Requirements

Core Requirement Specific Conditions
Chemicals (including hazardous substances and Industry Focus Process Chemicals (IFPC) List chemicals) are adequately and effectively managed on-site to minimize health and safety risk and impacts to the workers. On-site chemicals management is implemented for, at a minimum, the following elements:
• Inventory records and tracking methods
• Categorization
• Safe handling
• Storage
• Movement within premises
• Access management
Chemicals management documentation is accurate, up-to-date and maintained.
Worker exposure to chemical, biological, and physical hazards is controlled through measures appropriate to the risk. • Where workers may be exposed to multiple chemicals, exposure controls address the possibility and risk of combined exposure.
• Workplaces are free from obvious uncontrolled fumes, dust, odors, and other conditions indicating harmful exposure.
Worker exposure to IFPC List chemicals is adequately prevented by elimination or substitution, or mitigated by engineering controls, without any administrative controls or PPE.
Worker exposure and health are monitored through industrial hygiene monitoring and medical surveillance, and monitoring equipment is maintained and calibrated.

Additional Guidance

  1. Processes & Practices are in place such that:
    • a. There is proper budget and staffing allocated to conduct risk assessment, medical evaluations, provide PPE as well as training of individuals and coordination with local authorities as appropriate.

    • b. The Entity has conducted a risk assessment using established methodology to evaluate the risk of exposure to biological, chemical, and/or physical agents at the Entity. This is sometimes referred to as a qualitative exposure assessment to determine if there is a risk of exceeding exposure limits.

    • c. The need for exposure monitoring/air sampling is based on the results of the qualitative assessment and should occur if appropriate. Some countries require routine exposure monitoring regardless of the level of exposure.

      NOTE: Risk assessment should include exposure to multiple chemicals.

    • d. Where there is risk that the exposure may be significant, or when required by local regulations, the Entity conducts baseline (initial) and routine exposure monitoring/sampling to determine exposure levels to biological, chemical, and/or physical agents at the Entity.

    • e. The Entity has implemented controls to reduce or eliminate worker exposure to chemical, biological and physical agents:

      • i. Engineering controls (e.g. exhaust ventilation, enclosures, etc.) are designed to reduce worker exposure to chemical, biological and physical agents.
      • ii. Substitution of less hazardous chemicals and processes.
      • iii. Administrative controls (limiting worker exposure time; job rotation) are designed to reduce worker exposures to chemical, biological and physical agents.
      • iv. Appropriate Personal Protective Equipment (PPE) is issued to all workers only when engineering or administrative controls do not reduce exposures to acceptable levels.
    • f. Chemicals (including hazardous substances, IFPCs) are adequately and effectively.

      • i. Categorized
      • ii. Handled
      • iii. Stored
      • iv. Moved within a single Entity/ multiple Entities
      • v. Access is controlled.
      • vi. Potential employee exposure control methods are adequate and effective, such as
          1. Segregation
          1. Secondary containment
          1. Ventilation
          1. Fire protection
          1. Appropriate storage cabinets
      • vii. Proper marking of all chemical, biological, and physical agents to the stricter of regulations, GHS, or customer standards.
      • viii. SDSs are available in local languages for workers or a language that they can understand.

      NOTE: SDSs may be in physical form (e.g., paper) and available near to the area where the chemical is present or online. If they are online, workers must be trained and able to easily access the most current SDS.

  1. Controls & Monitoring include:
    • a. Regular evaluation plan to verify the effectiveness of implemented controls and corrective actions if required. The frequency should be at least every 3 years unless a Significant Change requires re-evaluation.
    • b. Approval is required for the purchase and use of hazardous chemicals and for all new purchases of hazardous chemicals before use.
    • c. Evaluations of chemicals (including hazardous chemicals) of less hazardous or non-hazardous alternatives, including Greenhouse Gas and ozone depletion impact.
    • d. Engineering controls are implemented to mitigate worker exposure effectively and adequately to substances containing IFPC List chemicals, which is demonstrated by industrial hygiene records.
    • e. IFPCs
      • i. An adequate and effective process for all hazardous chemicals to track, review, approve for use, and approve all new purchases of IFPCs before use.
      • ii. An adequate and effective program to control the identified potential hazards to chemical, biological, or physical agents is in place and follows the hierarchy of controls in a documented gated process, demonstrating that each hierarchy level has been fully evaluated.
      • iii. A prioritized review and selection process to eliminate, substitute or isolate workers from all IFPCs.
    • f. Monitoring, testing, alarm, and reporting equipment is available, well-maintained, calibrated, and operational.
  2. Records are maintained including:
    • a. Copies of hazardous substances inventory, manifests, and shipping papers are maintained and accurate.
    • b. Accurate chemical inventory records are maintained and accurate.
    • c. Inspection records of hazardous substances and their points of storage and use are maintained and accurate.
    • d. Worker testing, surveillance records to determine if the worker is being harmed from exposure to agents, respiratory, hearing loss or any other medical concerns related to specific job activities.
    • e. Equipment monitoring, testing, calibrating, and repair records.
    • f. Any other testing reports such as sampling records including sampling performed by government agencies as part of a regulatory inspection; all for the last three years.
  3. Leading Practices include:
    • a. Ongoing monitoring / air sampling even if not determined to be necessary or required by law.

Health and Safety Checklists

Note: These checklists are NOT assessment criteria. These are support tools for an Entity to guide their implementation of an appropriate system towards conformance to the RBA Code of Conduct.

  • Each checklist addresses different aspects of health and safety, and each aspect is addressed under its own title and set of questions.
  • For each question, three options to answer are available: Y (Yes), N (No) and N/A (Not Applicable), followed by the option to add comments.

B4 Industrial Hygiene – Hierarchy of Controls Checklist

Worker exposure to chemical, biological, and physical agents shall be identified, evaluated, and controlled according to the Hierarchy of Controls. When hazards cannot be adequately controlled, workers shall be provided with and use appropriate, well-maintained, personal protective equipment free of charge.

Hierarchy of Controls (from most effective to least effective):

  1. Elimination – Physically remove the hazard
  2. Substitution – Replace the hazard
  3. Engineering Controls – Isolate people from the hazard
  4. Administrative Controls – Change the way people work
  5. PPE – Protect the worker with Personal Protective Equipment

Source: NIOSH.

Site Observation:

Question Y N N/A Comments
a Adequate controls to reduce or eliminate worker exposure to chemical, biological and physical agents are in place and effective including:
• Proper design (elimination and/or substitution)
• Engineering controls (e.g. exhaust, ventilation, enclosures etc.)
• Administrative controls (e.g. limiting worker exposure time; job rotation etc.)
• Adequate and effective PPE
b Controls are implemented based on applicable legal requirements and result of risk assessments.
d During normal working hours, workplace is free from obvious odor, visible fumes, dust, and other conditions leading to potential unhealthy feelings (e.g. irritating chemical smell, eye irritating fume, etc.).

Risk assessment:

Question Y N N/A Comments
a Adequate and effective risk assessment with associated industrial hygiene sampling and testing is in place to identify and assess the potential hazards of chemical, biological, or physical agents.
b Significant Change has been defined in the risk assessment policy and procedure (e.g. introduction, elimination or change of a chemical).
c The risk assessment is updated when a Significant Change occurs.
d Risk assessment includes exposure to multiple chemicals:
Risk of combination effects of chemicals mixture are assessed.
Risk of chemicals by a single route as well as multiple routes are assessed. A route can be inhalation, ingestion, skin exposure, etc.

Control program:

Question Y N N/A Comments
a Adequate and effective program to control the identified potential hazards to chemical, biological, or physical agents based on applicable legal requirements and result of risk assessment is in place.
b The program to control identified potential hazards follows the hierarchy of controls from most effective to least effective.
c Regular evaluation plan to verify the effectiveness of implemented controls and corrective actions if required.
d Frequency to evaluate effectiveness of implemented controls is at least every three (3) years unless a major change or applicable law requires re-evaluation.

Records:

Question Y N N/A Comments
a Medical surveillance records are available for review pertaining to:
• Respiratory evaluations to determine if worker is being harmed from exposure to agents
• Determining hearing loss
• Any other medical concerns related to specific job activities, such as skin contact, hearing loss, radiation
Profiles using this criterion

RBA Assessment Program

Pass Threshold Metrics

Metric: Chemical Exposure

Type: Exposure vs limit
Threshold: 50% of PEL (<) → Conformance
Threshold: 80% of PEL (<) → Minor
Threshold: 100% of PEL (<) → Major
Threshold: 100% of PEL (>=) → Priority

Metric: SDS Availability

Type: % chemicals without SDS
Threshold: 0% → Conformance
Threshold: 5% (<=) → Minor
Threshold: 15% (<=) → Major
Threshold: 15% (>) → Priority

Conformity Alignment

Priority

Pass: No
Definition: "Critical non-conformance requiring immediate action"
Remediation: 30 days

Major

Pass: No
Definition: "Significant non-conformance requiring corrective action"
Remediation: 90 days

Minor

Pass: Yes
Definition: "Non-conformance with limited impact"
Conditions: Corrective action plan required
Remediation: 180 days

Opportunity

Pass: Yes
Definition: "Opportunity for improvement identified"

Conformance

Pass: Yes
Definition: "Full conformance with criterion requirements"

Related Criterion

VAP: Occupational Health and Safety

Relationship: Related
PPE requirements and hazard controls

VAP: Occupational Injury and Illness

Relationship: Related
Occupational illness from chemical exposure

VAP: Hazardous Substances

Relationship: Related
Environmental hazardous substance management

VAP: Health and Safety Management System

Relationship: Parent
Management system for health and safety practices

Change Log

5.0.0 (2026-09-27)

Changed

  • IFPC exposure must be controlled without admin controls/PPE; combined-exposure priority trigger removed: IFPC exposure must be prevented by elimination or substitution, or mitigated by engineering controls, 'without any administrative controls or PPE'. 8.0.3 allowed administrative controls or PPE for IFPCs in temporary circumstances or as a supplement to engineering controls. New core condition: workplaces are free from obvious uncontrolled fumes, dust, odours and other signs of harmful exposure (an 8.0.x checklist item, now mandatory). Worker exposure and health must be monitored through IH monitoring and medical surveillance as an unqualified core requirement. 8.0.3 required baseline/routine sampling only where exposure could be significant or law required it. The only priority trigger, 'not considering the COMBINED exposure to multiple chemicals', was removed (8.1 B4 has no serious-conditions list). Combined exposure is now an ordinary MCR condition: controls must address it where multiple chemicals are present. The chemicals-management minimum now explicitly includes inventory records and tracking methods, with accurate, current documentation. Risk assessment 'must' include multiple-chemical exposure was softened to 'should' (guidance). Re-assessment on new chemicals, the mitigation-tracking process and the gated-process 'reasons why' justification were dropped. PPE minimums (open-surface tanks, free PPE, training, enforcement) moved to B1 guidance.

4.0.0 (2024-01-01)

Changed

  • Added explicit numeric pass/fail thresholds for chemical exposure and SDS availability: Introduced numeric sub-thresholds that did not exist in any prior version (8.0.0 carried only generic 'See finding severity definition'). chemical_exposure vs PEL: <50% conformance, <80% minor, <100% major, >=100% priority. sds_availability (% chemicals without SDS): 0% conformance, <=5% minor, <=15% major, >15% priority. A finding such as 12% of chemicals missing an SDS, or exposure at 90% of PEL, could be rated minor and pass under 8.0.0 but falls in a defined major band under 8.0.1 — a prior pass can become a fail, hence major.

3.0.0 (2023-09-01)

Changed

  • Added mandatory monitoring-equipment and calibration-log requirements; ongoing health monitoring: The provision statement was extended to require control 'maintained through ongoing, systematic monitoring of worker's health.' A new mandatory Site Observation requires monitoring equipment to be available, well-maintained, calibrated and operational, and a new mandatory Record Review requires maintenance and calibration logs for monitoring equipment to be available, complete, accurate, and up-to-date. A facility passing 7.1.2 (which had no such requirement) but lacking calibrated/operational monitoring equipment or its calibration logs now fails — a prior pass can become a fail, hence major. The IFPC record mandate was also reworded from 'elimination/substitution/worker-isolation records' to 'engineering controls implemented to mitigate IFPC exposures, demonstrated by industrial hygiene records.'

2.0.0 (2022-06-01)

Changed

  • Introduced the Industry Focus Process Chemicals (IFPC) list and IFPC-specific record mandates: 7.0.0 B4 had no IFPC requirements. 7.1.2 added a mandatory IFPC list of 9 named chemicals (1-Bromopropane, Benzene, Methylene Chloride, Methanol, n-Hexane, NMP, Tetrachloroethylene, Toluene, Trichloroethylene) with IFPC-specific record-review mandates: accurate chemical inventory records, manifests and shipping papers maintained, approvals for the purchase of hazardous chemicals before use, elimination/substitution/ worker-isolation evaluation records for all IFPC, and a requirement that administrative controls or PPE be used for IFPC substances only in temporary circumstances. A facility that passed 7.0.0 while using e.g. Toluene without these IFPC records now fails — a prior pass can become a fail, hence major. The standalone permits/licenses/testing-reports provision (former B4.1) was removed and relocated to the H&S management-system clause (a concurrent loosening).

1.0.0 (2021-01-01)

Changed

  • Initial historical baseline — Industrial Hygiene (RBA Code of Conduct 7.0): Earliest imported version of the criterion. Identification, evaluation, and control of worker exposure to chemical, biological and physical agents according to the hierarchy of controls. Includes a standalone permits/licenses/testing-reports provision (B4.1) with a documented renewal process, a risk-assessment process updated on Significant Change, controls via elimination/substitution/engineering/administrative measures and PPE, a 3-year control-effectiveness evaluation cycle, and medical-surveillance records. No Industry Focus Process Chemicals (IFPC) requirements and no numeric pass/fail thresholds existed at this release.